Mains-Input FilterLarge Common-Mode ChokeLow-Frequency EMI Suppression

MF2 is a Mg-Zn ferrite (nickel-free) with an initial permeability (μi) of approx. 800, a saturation flux density (Bs) of approx. 270 mT at 25 °C (95 mT at 100 °C) and a Curie temperature above 130 °C. It is the high-permeability branch of the Mg-Zn line: at low frequencies it delivers impedance and inductance on par with the μi ≈ 800 NiZn grades at a clearly lower material cost; with a coercivity of only 16 A/m, hysteresis loss stays low and the loss factor is 25×10⁻⁶ at 0.1 MHz / 50×10⁻⁶ at 0.5 MHz. Typical uses are mains-input filters, large common-mode chokes and low-frequency EMI suppression. Against L43 at the same nominal μi of 800, MF2 is the economy option while L43 is the EMI-characterised option (broadband suppression with dual-fixture impedance data); since only about 95 mT of flux remains at 100 °C and Tc is >130 °C, switch to the NiZn grades for hot or high-current duties.

Magnetic Characteristics

CharacteristicConditionValueUnit
μiInitial Permeability100 kHz & <0.2 mT800±25%—
BsSaturation Flux Density3000 A/m · 25 ℃100 Hz270mT
BsSaturation Flux Density3000 A/m · 100 ℃100 Hz95mT
BrRemanence3000 A/m · 25 ℃100 Hz125mT
BrRemanence3000 A/m · 100 ℃100 Hz8mT
HcCoercivity3000 A/m · 25 ℃100 Hz16A/m
HcCoercivity3000 A/m · 100 ℃100 Hz6A/m
αμrTemperature coefficient of permeability20~60 ℃15×10⁻⁶/K
tanδ/μiRelative Loss Factor0.1 MHz & <0.2 mT25×10⁻⁶
tanδ/μiRelative Loss Factor0.5 MHz & <0.2 mT50×10⁻⁶
TcCurie Temp.100 kHz & <0.2 mT>130℃
DDensityArchimedes method4.85g/cm³
ρVolume ResistivityDC Current10⁷Ω·m

Characteristic curves

CURVE 01 · Initial Permeability vs. TemperatureInitial Permeability vs. Temperature
CURVE 02 · Complex Permeability (μ′, μ″) vs. FrequencyComplex Permeability (μ′, μ″) vs. Frequency
CURVE 03 · Static Magnetization Curves (B–H)Static Magnetization Curves (B–H)
CURVE 04 · Relative Loss Factor (tanδ/μi) vs. FrequencyRelative Loss Factor (tanδ/μi) vs. Frequency

Applications

ApplicationRoleBandTemperature
Cost-effective inductor / EMI (Mg-based: Ni-Mg-Zn / Mg-Zn)First choice0.1–0.7 MHz—

Used in circuits