MnZn Power Ferrite · Mid-frequency power · Material specification

TP45

HIGHER-PERMEABILITY LOW-LOSS POWER FERRITE

Flyback TransformerAdapter / ChargerTelecom PowerHalf-Bridge / LLC Transformer

TP45 is a higher-permeability MnZn power ferrite with an initial permeability (μi) of 2500, a saturation flux density (Bs) of 500 mT at 25 °C (400 mT at 100 °C) and a Curie temperature above 210 °C. A μi 25 % above TP40/TP44 reduces the number of turns for a given magnetising inductance, so flyback and adapter transformers require fewer winding layers and exhibit lower leakage, without a loss penalty: 600 → 300 kW/m³ at 100 kHz / 200 mT, equivalent to TP44; 620 → 420 kW/m³ at 300 kHz / 100 mT; and 270 → 200 kW/m³ at 500 kHz / 50 mT, so the usable band extends to low-flux operating points around 500 kHz; at 100 °C the coercivity (Hc) is 7 A/m and the remanence (Br) 70 mT. Typical applications are flyback transformers for adapters and chargers, telecom supplies and 300 kHz-class half-bridge/LLC transformers. Among the six mid-frequency grades TP45 is distinguished by μi: it is recommended where turns and leakage are the design constraint, TP44 where an existing μi 2000 turns design is retained and loss must be reduced, and TP40 for large general-purpose cores. Its Bs retention at 100 °C is 80 %, the same as TP44; the hot-state saturation margin should be calculated at 400 mT.

Magnetic Characteristics

CharacteristicCondition25 ℃100 ℃Unit
Initial Permeability μiInitial Permeability μi100 kHz & <0.2 mT2500±25%——
Amplitude Permeability μaAmplitude Permeability μa25 kHz/400 mT> 4000> 3500—
Saturation Flux Density BsSaturation Flux Density Bs1200 A/m 100 Hz500400mT
Remanence BrRemanence Br1200 A/m 100 Hz13070mT
Coercivity HcCoercivity Hc1200 A/m 100 Hz107A/m
Loss FactorLoss Factor100 kHz & <0.2 mT<10—10⁻⁶
Curie Temperature TcCurie Temperature Tc100 kHz & <0.2 mT>210—℃
Density DDensity DArchimedes method4.8—g/cm³
Electrical Resistivity ρElectrical Resistivity ρDC Current>6—Ω·m

Power Loss · kW/m³

Condition25 ℃100 ℃
100 kHz/200 mT600300
300 kHz/100 mT620420
500 kHz/50 mT270200

Pcv = K·f^α·B^β

RangeKαβ
80 ≤5007.85E-081.872372.54868
100 ≤5004.75E-071.74142.35204

Characteristic curves

CURVE 01curve
CURVE 02curve
CURVE 03curve
CURVE 04curve
CURVE 05curve
CURVE 06curve

Applications

ApplicationRoleBandTemperature
Flyback transformer (>150 W)Alternative≤0.3 MHz60–80 ℃
Forward transformerAlternative≤0.3 MHz60–80 ℃
Push-pull transformerAlternative≤0.3 MHz60–80 ℃
LLC / resonant & bridge transformer (incl. Lr)Alternative≤0.3 MHz60–80 ℃
Buck output inductorAlternative≤0.3 MHz60–80 ℃