MnZn Power Ferrite · Conventional low-frequency power · Material specification

T2

LOW-FREQUENCY LOW-LOSS POWER FERRITE

Electronic Ballast InductorLow-Frequency Power TransformerWideband BalunCurrent Transformer

T2 is a low-frequency low-loss MnZn power ferrite with an initial permeability (μi) of 2800, a saturation flux density (Bs) of 510 mT at 25 °C (390 mT at 100 °C) and a Curie temperature above 180 °C. Its loss minimum lies at room temperature: 110 kW/m³ at 25 °C rising to 200 kW/m³ at 100 °C at 25 kHz / 200 mT, and 110 → 240 kW/m³ at 100 kHz / 100 mT, the lowest of the three conventional low-frequency grades at both conditions and both temperatures; a μi of 2800 minimises the number of turns for a given inductance at low frequency, reducing copper loss and winding volume accordingly. Typical applications are electronic-ballast inductors below 100 kHz, low-frequency switch-mode transformers, wideband baluns and current transformers. Among the three conventional low-frequency grades T2 is the loss reference: T2M (410 mT at 100 °C) is recommended where the core operates at elevated temperature or a higher 100 °C Bs is required, TB2 where a square hysteresis loop is required, and the high-Bs special grade TM82 for PFC and storage chokes under DC bias. Since its loss increases with temperature and its Bs retention at 100 °C (76 %) is comparatively low for a power grade, the thermal design should keep the core at moderate temperature.

Magnetic Characteristics

CharacteristicCondition25 ℃100 ℃Unit
Initial Permeability μiInitial Permeability μi100 kHz & <0.2 mT2800±25%——
Amplitude Permeability μaAmplitude Permeability μa25 kHz/400 mT> 1000> 500—
Saturation Flux Density BsSaturation Flux Density Bs1200 A/m 100 Hz510390mT
Remanence BrRemanence Br1200 A/m 100 Hz135110mT
Coercivity HcCoercivity Hc1200 A/m 100 Hz1510A/m
Loss FactorLoss Factor100 kHz & <0.2 mT< 12—10⁻⁶
Curie Temperature TcCurie Temperature Tc100 kHz & <0.2 mT>180—℃
Density DDensity DArchimedes method4.80—g/cm³
Electrical Resistivity ρElectrical Resistivity ρDC Current>5—Ω·m

Power Loss · kW/m³

Condition25 ℃100 ℃
25 kHz/200 mT110200
100 kHz/100 mT110240

Characteristic curves

CURVE 01curve
CURVE 02curve
CURVE 03curve
CURVE 04curve
CURVE 05curve
CURVE 06curve

Applications

ApplicationRoleBandTemperature
Low-frequency power / ballasts (≤0.1 MHz)First choice≤0.1 MHz—
Current transformerAlternative≤0.1 MHz—