TAK Technology
Soft ferrite · NiZn & MnZn
From formulation to core
TAK / Company profile 2027
06 / Catalogue
Materials

All grades

TTechnology
AAssurance
KKeeper

MnZn Power Ferrite · Conventional low-frequency power · Material specification

T2M

LOW-FREQUENCY HIGH-FLUX POWER FERRITE

Electronic BallastLow-Frequency Power TransformerEnergy-Storage Choke

T2M is a low-frequency high-flux MnZn power ferrite with an initial permeability (μi) of 2000, a saturation flux density (Bs) of 510 mT at 25 °C (410 mT at 100 °C) and a Curie temperature above 220 °C. Compared with T2 its Bs at 100 °C is 20 mT higher (410 vs 390 mT, 80 % vs 76 % retention), i.e. Bs decreases more slowly with temperature; the coercivity (Hc) is 10 A/m at both 25 °C and 100 °C, so the hysteresis characteristic does not drift with temperature. Loss is somewhat higher than T2 (25 kHz / 200 mT: 270 → 330 kW/m³; 100 kHz / 100 mT: 360 → 520 kW/m³) but within the normal range of low-frequency power grades. Typical applications are electronic ballasts, low-frequency power transformers and storage chokes below 100 kHz with elevated core temperature. Among the three conventional low-frequency grades T2M is the temperature-oriented grade: T2 is recommended where loss is the priority and the core temperature is moderate, TB2 where a square loop and 460 mT of hot-state Bs are required, and the high-Bs special grade TM82 where 500 mT of hot-state Bs and DC-bias tolerance are required. Selection should be based on the hot-state saturation margin rather than on room-temperature μi — its μi is below that of T2; its advantage is hot-state Bs.

Magnetic Characteristics

CharacteristicCondition25 ℃100 ℃Unit
Initial Permeability μiInitial Permeability μi100 kHz & <0.2 mT2000±25%——
Amplitude Permeability μaAmplitude Permeability μa25 kHz/400 mT> 500> 500—
Saturation Flux Density BsSaturation Flux Density Bs1200 A/m 100 Hz510410mT
Remanence BrRemanence Br1200 A/m 100 Hz130130mT
Coercivity HcCoercivity Hc1200 A/m 100 Hz1010A/m
Loss FactorLoss Factor100 kHz & <0.2 mT< 25—10⁻⁶
Curie Temperature TcCurie Temperature Tc100 kHz & <0.2 mT> 220—℃
Density DDensity DArchimedes method4.90—g/cm³
Electrical Resistivity ρElectrical Resistivity ρDC Current>6—Ω·m

Power Loss · kW/m³

Condition25 ℃100 ℃
25 kHz/200 mT270330
100 kHz/100 mT360520

Characteristic curves

CURVE 01curve
CURVE 02curve
CURVE 03curve
CURVE 04curve
CURVE 05curve
CURVE 06curve

Applications

ApplicationRoleBandTemperature
Low-frequency power / ballasts (≤0.1 MHz)First choice≤0.1 MHz—

Used in circuits

Overview ⤢ ←→Switch chapter · EscBack to overview