TAK Technology
Soft ferrite · NiZn & MnZn
From formulation to core
TAK / Company profile 2027
06 / Catalogue
Materials

All grades

TTechnology
AAssurance
KKeeper

MnZn Power Ferrite · Conventional low-frequency power · Material specification

TB2

HIGH-SQUARENESS POWER FERRITE

Magnetic AmplifierSaturable ReactorBallast Trigger CoreSwitching Choke

TB2 is a high-squareness MnZn power ferrite with an initial permeability (μi) of 1500, a saturation flux density (Bs) of 580 mT at 25 °C (460 mT at 100 °C) and a Curie temperature above 220 °C. Its characteristic feature is a remanence (Br) of 420 mT at 25 °C (330 mT at 100 °C), a squareness ratio Br/Bs of about 0.72 and a near-rectangular hysteresis loop: the core switches distinctly between its two saturated states and retains most of its flux after excitation is removed, which is the operating principle of magnetic amplifiers and saturable reactors. The corresponding penalty is a coercivity (Hc) of 30 A/m at 25 °C (25 A/m at 100 °C) and higher loss (25 kHz / 200 mT: 310 → 430 kW/m³; 100 kHz / 100 mT: 440 → 760 kW/m³). Typical applications are mag-amp regulators, saturable reactors, ballast trigger cores and switching chokes. Among the three conventional low-frequency grades TB2 is the only one selected for squareness: low-loss transformer and choke duty is served by T2/T2M, and higher Bs and DC-bias tolerance by the high-Bs special grade TM82. The grade is intended for circuits requiring switching-type magnetisation and is not recommended for linear transformers.

Magnetic Characteristics

CharacteristicCondition25 ℃100 ℃Unit
Initial Permeability μiInitial Permeability μi100 kHz & <0.2 mT1500±25%——
Amplitude Permeability μaAmplitude Permeability μa25 kHz/400 mT> 900> 500—
Saturation Flux Density BsSaturation Flux Density Bs1200 A/m 100 Hz580460mT
Remanence BrRemanence Br1200 A/m 100 Hz420330mT
Coercivity HcCoercivity Hc1200 A/m 100 Hz3025A/m
Loss FactorLoss Factor100 kHz & <0.2 mT< 40—10⁻⁶
Curie Temperature TcCurie Temperature Tc100 kHz & <0.2 mT>220—℃
Density DDensity DArchimedes method4.90—g/cm³
Electrical Resistivity ρElectrical Resistivity ρDC Current>4—Ω·m

Power Loss · kW/m³

Condition25 ℃100 ℃
25 kHz/200 mT310430
100 kHz/100 mT440760

Characteristic curves

CURVE 01curve
CURVE 02curve
CURVE 03curve
CURVE 04curve
CURVE 05curve
CURVE 06curve

Applications

ApplicationRoleBandTemperature
Low-frequency power / ballasts (≤0.1 MHz)First choice≤0.1 MHz—

Used in circuits

Overview ⤢ ←→Switch chapter · EscBack to overview