NiZn Ferrite · NiZn material specification

Q1C1

HIGH FREQUENCY STABLE MATERIALS

Low-Frequency EMI FilterRF Tuning ElementCompact Power-Module InductorEMI Suppression Bead

Q1C1 is a NiZn ferrite with an initial permeability (μi) of approx. 250, a saturation flux density (Bs) of approx. 335 mT at 25 °C (240 mT at 100 °C) and a Curie temperature above 140 °C. It is the high-permeability end of the high-frequency family: a loss factor of only 35×10⁻⁶ at 0.5 MHz / 45×10⁻⁶ at 2.5 MHz is remarkably low for this permeability step, and the high inductance per turn favours miniaturisation. As an EMI-suppression material its normalized impedance is measured on an RH5×1.5×10 bead (curve on the next page). Typical uses are low-frequency EMI filters, RF tuning elements and compact power-module inductors. Against M63 (μi approx. 180, Tc >300 °C), Q1C1 offers higher inductance density at a clearly lower Curie temperature (>140 °C) — fall back to M63/M61 in harsh thermal environments; for compact room-temperature designs Q1C1 is the family's first choice.

Magnetic Characteristics

CharacteristicConditionValueUnit
μiInitial Permeability100 kHz & <0.2 mT250±25%—
BsSaturation Flux Density3000 A/m · 25 ℃100 Hz335mT
BsSaturation Flux Density3000 A/m · 100 ℃100 Hz240mT
BrRemanence3000 A/m · 25 ℃100 Hz200mT
BrRemanence3000 A/m · 100 ℃100 Hz130mT
HcCoercivity3000 A/m · 25 ℃100 Hz140A/m
HcCoercivity3000 A/m · 100 ℃100 Hz140A/m
αμrTemperature coefficient of permeability20~60 ℃10×10⁻⁶/K
tanδ/μiRelative Loss Factor0.5 MHz & <0.2 mT35×10⁻⁶
tanδ/μiRelative Loss Factor2.5 MHz & <0.2 mT45×10⁻⁶
TcCurie Temp.100 kHz & <0.2 mT>140℃
DDensityArchimedes method4.9g/cm³
ρVolume ResistivityDC Current10⁷Ω·m

Characteristic curves

CURVE 01 · Initial Permeability vs. TemperatureInitial Permeability vs. Temperature
CURVE 02 · Complex Permeability (μ′, μ″) vs. FrequencyComplex Permeability (μ′, μ″) vs. Frequency
CURVE 03 · Static Magnetization Curves (B–H)Static Magnetization Curves (B–H)
CURVE 04 · Relative Loss Factor (tanδ/μi) vs. FrequencyRelative Loss Factor (tanδ/μi) vs. Frequency
CURVE 05 · Normalized Impedance ZN vs. Frequency (single turn of Φ0.5 mm wire, 100 mm long)Normalized Impedance ZN vs. Frequency (single turn of Φ0.5 mm wire, 100 mm long)

Applications

ApplicationRoleBandTemperature
Small-power HF transformer (low flux)Alternative0.5–3.5 MHz—
Wideband signal transformer / balunFirst choice≤3.5 MHz—
Antenna rod / RFID / high-Q inductorFirst choice0.1–2.2 MHz—
Low-μ tuning / HF resonanceFirst choice0.1–2.2 MHz—
EMI bead / ring / cable sleeveAlternative100–300 MHz—

Used in circuits